1800 266 8222

From Irrigation to harvest, its india's tru choice

Agricultural Piping systems for pressure-resistance

Agricultural PipingSystems

trubore-standard-product

Pipes as per
IS:13592
isi-mark

Fitting as per
IS:14735
isi-mark

Extensively used in
  • Hospital
    Agriculture

Agricultural Piping System

TRUBORE offers the highest range of uPVC Pipes & Fittings TRUBORE is crafted to perfection with the highest rating of ISI with a wide range from 20mm to 250mm and working pressure mark and is available through a wide-spread network of around of 10kg/cm 2 , 6kg/cm 2 and 4kg/cm 2 as well as non-pressure 3500 dealers spread across the country. fittings.

Applications

In Agriculture

  • Water supply and distribution schemes.
  • Irrigation

Others

  • Drinking Water supply and distribution.
  • Cable ducting.
  • Ventilation pipe line.
  • Slurry lines

Major Advantages

  • Light weight, easy to transport, store, handle and install..
  • Smooth bore ensures higher flow compared to G.I. pipes & fittings of the same size. No clogging. Saves operational cost.
  • Quick to install, solvent cement based jointing system.
  • Corrosion resistance - uPVC is rustproof material therefore, bore diamater remains constant, ensuring constant flow over its lifetime.
  • Long working life (if operated under normal/recommended conditions).
  • Cost-effective. Added value for your money

STANDARDS, QUALITY CONTROL & TESTING

The manufacturing and testing is done for Pipes in accordance with IS: 4985 - 2000.

All the above pipes, except non-pressure pipes are tested for potable water supplies in accordance with their relevant standards and as per the test methods given in IS: 12235.

COEFFICIENT COMPARISON

Pipe MaterialPVCA.C.G.I.C.I.
Flow Coefficient150130110100

Pipes

All dimensions are in mm
Nominal Outside Diameter (Nominal Size)Mean Outside DiameterOutside Diameter at any pointWall Of Thickness(mm)Mean Socket Internal Diameter of Mid Point of Socket Length
Class 1
0.25 MPa
2.5 Kg/cm²
Class 2
0.40 MPa
4.0 Kg/cm²
Class 3
0.60 MPa
6.0 Kg/cm²
Class 4
0.80 MPa
8.0 Kg/cm²
Class 5
1.00 MPa
10.0 Kg/cm²
Class 6
1.25 MPa
12.5 Kg/cm²
MinMaxMinMaxMinMaxMinMaxMinMaxMinMaxMinMaxMinMaxMinMax
2020.020.0319.520.5--------1.11.51.41.820.120.3
2525.025.024.525.5------1.21.61.41.81.72.125.125.3
3232.032.331.532.5------1.51.91.82.22.22.732.132.3
4040.040.339.540.5----1.41.81.82.22.22.72.83.340.140.3
5050.050.349.450.6----1.72.12.32.82.83.33.44.050.150.3
6363.063.362.263.8--1.51.92.22.72.83.33.54.14.35.063.163.3
7575.075.374.175.9--1.82.22.63.13.44.04.24.95.15.975.175.3
9090.090.388.991.11.31.72.12.63.13.74.04.65.05.76.17.190.190.3
110110.0110.4108.6111.41.62.02.53.03.74.34.95.66.17.17.58.7110.1110.4
125125.0125.4123.5126.51.82.22.93.44.35.05.66.46.98.08.59.8125.1125.4
140140.0140.5138.3141.72.02.43.23.84.85.56.37.37.78.99.511.0140.2140.5
160160.0160.5158.0162.02.32.83.74.35.46.27.28.38.810.210.912.6160.2160.5
180180.0180.6177.8182.22.63.14.24.96.17.18.09.29.911.412.214.1180.2180.5
200200.0200.6197.6202.42.93.44.65.36.87.98.910.311.012.713.615.7200.3200.6
225225.0225.7222.3222.73.33.95.26.07.68.810.011.512.414.315.317.6225.3225.7
250250.0250.8247.0253.03.64.25.76.58.59.811.212.913.815.917.019.6250.4250.8
280280.0280.9276.6283.44.14.86.47.49.511.012.514.415.417.819.021.9280.4280.9
315315.0316.0311.2318.84.65.37.28.310.712.414.016.117.319.921.424.7315.4316.0
355355.0356.1350.7359.35.15.98.19.412.013.815.818.219.622.624.127.8355.4356.0
400400.0401.2395.2404.85.86.79.110.513.515.617.820.522.025.327.231.3400.4401.0

Note: All pipes are avialable with ISI Mark except 400mm .

Fittings

Coupler 6kg

Know More

Coupler 10Kg

Know More

Coupler LW

Know More

Elbow 6Kg

Know More

Elbow 10Kg

Know More

Elbow LW

Know More

End Cap 6Kg

Know More

End Cap 10Kg

Know More

End Cap LW

Know More

End Cap Threaded

Know More

F.T.A

Know More

M.T.A

Know More

Reducer

Know More

Reducing Bush

Know More

Reducing Tee

Know More

Reducing Tee LW

Know More

Tee 6Kg

Know More

Tee 10Kg

Know More

Tee LW

Know More

F.T.A Brass Insert

Know More

F.T.Elbow Brass Insert

Know More

F.T.Tee Brass Insert

Know More

Service Saddle

Know More

DO's & Dont's

Chamfering

  • After cutting, the pipe needs to be chamfered from the outer sides. It is advisable to provide approximately 2mm wide, 150 chamfer on spigot end.
  • Do not proceed with installation of pipe without chamfering.

Dryfit

  • Before applying solvent cement, insert the pipe-end into the socket of the next pipe or fitting to check if interference occurs at about 1/3. to 2/3. of the socket depth.
  • Do not apply solvent cement without conducting Dryfit Test.

Application of Solvent Cement

  • Mark the pipe length to be inserted for jointing. Apply a liberal coat of solvent cement with the help of the
  • Do not apply excess solvent cement on the pipe and do not use solvent cement by hand.

Jointing

  • Push the pipe inside the fitting so that it goes inside it equally from all the sides. Wipe off excess solvent cement that comes out from all the edges. Hold the joint for 2 minutes so that the jointing is perfect.
  • Do not use a hammer or half push the pipe.
  • FOR THREADED JOINTS
    Don't over tighten with pipe wrench.

Cutting

  • It's imperative to mark the pipe from all sides so that pipe is cut with the help of Hand Saw.It should be a right angle cut from all sides. The cut piece should be with burr on edges
  • Do not cut slant or unevenly.

Derubbing and
Ridge Removal

  • Remove all the burr and ridges accumulated on the inner as well as the outer edges of the pipe with the help of deburring Knife,file or abrasive paper.
  • Do not proceed with installation of pipe without deburring.

Cleaning

  • Thoroughly clean the pipe with a dry cloth where the solvent cement is going to be applied,to avoid dust,dirt,oil,moisture and other foreign material during the installation process.
  • Do not join the pipe without cleaning the pipe ends.

Specifications

Fittings
MaterialUnplasticized Polyvinyl Chloride (uPVC)
ColourDark Grey
Reference StandardsIS 7834 : 1987
Working Temperature of Fluids Up to 60°C – Continuous, Up to 90°C – Short time, Up to 3 mins.
Working Pressure (kg/cm²)4, 6, 10 & 16
End ConnectionsSolvent sockets, Threads (For transition fittings)

HAZEN - WILLIAM’S FLOW

Pipe MaterialPVCA.C.G.I.C.I.
Flow Coefficient150130110100

Properties of uPVC Pipes

Mechanical
Tensile Strength415 - 525 kg/cm²
Compression Strength550 - 910 kg/cm²
Flexural Strength680 - 1100 kg/cm²
Izod Impact Strength4 - 5 kg/cm²
Shore HardnessD 65 - 85
THERMAL
Coefficient of Linear Expansion0.08 mm/M°C
Vicat Softening Temperature> 78°C
Max. Operating Temperature60°C
Physical
Specific Gravity1.40 - 1.46
Water Absorption < 4mg/cm³